- Add a PM variable to the cases step
- Problema resuelto, se validara la variable $_SESSION["PROCESSMAKER_RUN_OUTSIDE_MAIN_APPLICATION"],
si se ha definido la variable no se ejecutara el fragmento de codigo, si variable no esta definido se ejecutara el
fragmento de codigo.
* Available from version ProcessMaker-2.5.1-testing.2
- When 1 trigger is created in a process trigger list of Events is empty
- Problem solved, to create an event of type Conditional Intermediate or Intermediate Timer, the label
"Execute Trigger" shows everyone Triggers created.
* Available from version ProcessMaker-2.5.1-testing.2
- Texto "required field" del pie de creacion de campos de un dynaform no se visualiza.
- Problema resuelto, el texto "required field" del pie de creacion de campos de un dynaform,
se visualiza en los en Firefox, IE y Chrome.
* Available from version ProcessMaker-2.5.1-testing.2
- Cuando se pausa un hilo el status de todo el caso cambia a PAUSED
- Ya no se cambia el status de todo el caso, solo se cierra el hilo pausado
- Existe aun un problema con los listados, los cuale sno muestran el estado del caso correctamente, eso se arreglara con el bug 11791 y 12012
On Admin > Users > Roles > choose Operator or Manager Role > Users > Assign Users, click on Administrator from the Available Users List and then assign this to the Assigned Users List, PM allowed you assign the Administrator user to the Operator/Manager Role. Now PM shows a notification popup saying this is not allowed.
On Admin > Users > Roles > choose Operator or Manager Role > Users > Assign Users, click on Administrator from the Available Users List and then assign this to the Assigned Users List, PM allowed you assign the Administrator user to the Operator/Manager Role. Now PM shows a notification popup saying this is not allowed.
In Home Tab when you loss session, PM naver advise it to you, and it still working but dosen't save the data.
So now all Home places are validated to show a popup message when you loos session.
- Al restaurar la sesion no estaba seteandose los valores correctos en el archivo del formulario en c"ommpiled"
- Al restaurar la sesion se crea un nuevo file en compiled con los datos actualizados
- Al parecer existe un problema de concurrencia al crear los casos en processmaker, de tal forma que si se intenta crear 2 casos al mismo tiempo el número del caso termina siendo el mismo para ambos casos.
- Centralized incrementing of the sequence of the cases of the application.
- Cuando se abre el boton action del nuevo evento, se da un fatal error.
- Problema resuelto, al crear un evento de tipo Intermediate Message al hacer click en el boton Action
ya no muestra el error.